Automationdirect.com FPM-180 User Manual

Browse online or download User Manual for TVs & monitors Automationdirect.com FPM-180. ProSense TSD25 Series Temperature Switches

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
www.automationdirect.com/temperature-sensors
Temperature Sensors
eTE-5
Prices as of April 16, 2014. Check Web site for most current prices.
TSD25 Series Temperature Switches
ProSense TSD25 Series Technical Specifications
TSD25N-AP-0284-H TSD25N-0P-0284-H
Operating Voltage
9.6 to 32 VDC
Process Connection
1/4” MNPT
Electrical Connection
M12 connector; gold-plated contacts
Outputs
Two PNP N.O. switching DC outputs Two complementary PNP (1-N.O./1-N.C.) switching DC outputs
Current Rating
500 mA each output
Current Consumption
< 30 mA
Short-Circuit Protection
Yes (non-latching)
Reverse Polarity Protection
Yes
Overload Protection
Yes
Voltage Drop
< 2 VDC
Pressure Rating
4350 psi (300 bar)
Set point scale
-4 to 284°F(-20 to 140°C) 3 to 284°F(-16 to 140°C)
Reset point scale
Fixed 5°C below setpoint -4 to 277°F(-20 to 136°C)
Adjustment of the Switch Point
Setting dials
Setting Accuracy
± 3°C
Repeatability
± 0.1% of full range in °C
Temperature Drift
± 0.1%, of full temperature range/10°C; 32 to 176°F (0 to 80°C).
Power-on Delay Time
0.5 seconds
Measuring Element
1 x Pt 1000, to DIN EN 60751, class B
Dynamic Response (DIN EN 60751)
*t0.5 = 1 sec/ t0.9 = 3 sec
Minimum Installation Depth
0.6 in (15 mm)
Housing Material
PBT (Pocan); PC (Makrolon); FPM (Viton); stainless steel (316S12)
Materials (wetted parts)
Stainless steel (316S12)
Display
Switching Status: 2 LEDs: yellow Power: LED - green - Switching Status: LED - yellow
Ambient Temperature
–13 to 158°F (–25 to 70°C)
Medium Temperature
–13 to 257°F (–25 to 125°C) continuous, 258 to 293°F (126 to 145°C) 1 hour max
Storage Temperature
–40 to 212°F (–40 to 100°C)
Protection
IP 67, Class III
Insulation Resistance
> 100 MΩ (500 VDC)
Shock Resistance
50g (DIN / IEC 68-2-27, 11ms)
Vibration Resistance
20g (DIN / EN 68-2-6, (10 to 2000 Hz)
EMC
EN 61000-4-2 ESD
4 kV CD/8 kV AD
EN 61000-4-3 HF Radiated
10 V/m
EN 61000-4-4 Burst
2 kV
EN 61000-4-6 HF Conducted
10 V
Features
• Compact temperature switch with simple setup
using mechanical adjustment dials
• Extremely durable housing with 316 stainless
steel wetted parts
• No internal moving parts ensure long-term
stability without setpoint drift
• LEDs indicate switching and operating status
• Two normally open or complementary normally
open/normally closed PNP DC switching outputs
• Optional plastic protective cover: PSD-CV
Agency Approvals
• cULus, File number E324411
• CE
• RoHS
* t
0.5
= a 50% of full scale change in output when immersed in water at 0.4m/s, t
0.9
= a 90% FS change.
NOTE: CHECK THE CHEMICAL COMPATIBILITY OF THE SENSORS WETTED PARTS WITH THE MEDIUM TO BE MEASURED.
www.automationdirect.com/static/specs/prosensechemresistance.pdf
ProSense Series Temperature Sensors
Part Number Description Pcs/Pkg Wt(lb) Price Use With
TSD25N-0P-0284-H
Temperature switch, two PNP complementary (1NO/1NC) switching DC outputs
adjusted by setting dials.1/4 inch NPT male port, 4-pin micro M12 DC plug,
Set point scale: 3 to 284°F (-16 to 140°C). Probe length: 35 mm [1.38 inches]
1 0.25 $89.75 PSD-CV
TSD25N-AP-0284-H
Temperature switch, two PNP (NO) switching DC outputs adjusted separately by
setting dials with a fixed 9°F hysterisis. 1/4 inch NPT male port, 4-pin micro
M12 DC plug, Set point scale: -4 to 284°F (-20 to 140°C). Probe length: 35
mm [1.38 inches]
1 0.25 $89.75 PSD-CV
Note: Purchase cable separately
Book 2 (14.1)
Company
Information
Drives
Soft Starters
Motors
Power
Transmission
Motion: Servos
and Steppers
Motor Controls
Sensors:
Proximity
Sensors:
Photoelectric
Sensors:
Encoders
Sensors:
Limit Switches
Sensors:
Current
Sensors:
Pressure
Sensors:
Temperature
Sensors:
Level
Sensors:
Flow Switches
Pushbuttons
and Lights
Stacklights
Signal
Devices
Process
Relays and
Timers
Pneumatics:
Air Prep
Pneumatics:
Directional Control
Valves
Pneumatics:
Cylinders
Pneumatics:
Tubing
Pneumatics:
Air Fittings
Appendix
Book 2
Terms and
Conditions
Page view 0
1 2 3 4 5 6 ... 13 14

Summary of Contents

Page 1 - Features

www.automationdirect.com/temperature-sensorsTemperature SensorseTE-5Prices as of April 16, 2014. Check Web site for most current prices.TSD25 Series T

Page 2 - 1-800-633-0405

Sensor Cables and ConnectorsM12 Patch Cables with LED Indicator (Euro, Micro DC-Single Key)Part NumberPrice Length Poles Connectors LED Jacket Dimensi

Page 3

Sensor Cables and ConnectorsCable SpecificationsSpecification M8 M12 M12 with LEDLength1m (3.28 ft.) / 3m (9.84 ft.)0.3m (0.98 ft) / 0.6m (1.97 ft) / 1m

Page 4

Sensor Cables and ConnectorsFigure 1Figure 2Figure 3Figure 4Dimensions mm [inches]Figure 5Figure 6Figure 71-800-633-0405Wiring SolutionseWD-80Prices

Page 5

Sensor Cables and ConnectorsM8 Cables with Quick-Disconnect Part Number Price Length Poles Connectors Jacket DimensionsM8 Quick-DisconnectsCD08-0G-020

Page 6

1-800-633-0405eTE-76Temperature SensorsBook 2 (14.1)Prices as of April 16, 2014. Check Web site for most current prices.Thermocouple and RTDTemperatur

Page 7

1-800-633-0405eTE-6Temperature SensorsBook 2 (14.1)Prices as of April 16, 2014. Check Web site for most current prices.TSD25 Series Temperature Switch

Page 8

Cables with quick-disconnect plugs• Industry standard axial and right-angle M8/M12 screw-lock connectors with open leads. The cables listed can be u

Page 9

• Industry standard M12 right angle femaleplug with open leads• These cables can be used with patch cables.• 2m, 5m and 10m cable lengths• PUR (po

Page 10 - Sensor Cables and Connectors

Sensor Cables and ConnectorsCable SpecificationsSpecification M8M12CD Series 7000 Series (unshielded)Length2m (6.5 ft) /7m (23 ft)5m (16.4 ft)2m (6.5 ft

Page 11

Cable SpecificationsSpecificationM127000 Series (shielded)M12 with LEDLength5m (16.4 ft) / 10m (32.8 ft)2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft)Nomina

Page 12

Sensor Cables and ConnectorsDimensions mm [inches]Figure 1Figure 2Figure 3 Figure 4Figure 5Figure 6Figure 7Figure 8eWD-75www.automationdirect.com/wiri

Page 13

Sensor Cables and ConnectorsFigure 9 Figure 10Figure 11Figure 12Dimensions mm [inches]Figure 13Figure 14Figure 15Figure 161-800-633-0405Wiring Solutio

Page 14 - Temperature Range

Sensor Cables and ConnectorsFigure 17Figure 18Figure 19Dimensions mm [inches]Figure 20Figure 21Figure 22Figure 23Figure 24Figure 26Figure 25eWD-77www.

Comments to this Manuals

No comments